Analysis of Polymers, Additives and Contaminates in Medical Devices using Pyrolysis-GCMS
EP22872
Poster Title: Analysis of Polymers, Additives and Contaminates in Medical Devices using Pyrolysis-GCMS
Submitted on 06 Apr 2015
Author(s): Gary Deger
Affiliations: CDS Analytical
This poster was presented at Pittcon
Poster Views: 1,420
View poster »


Poster Information
Abstract: Polymers and additives are used in a variety of subcutaneous and intravascular medical devices, such as sutures and drug delivery systems. These devices typically can be classified as being either absorbable or non-absorbable by the human body. Natural materials, such as silk and catgut, are largely being replaced by synthetic materials. So, the reliability of these devices relies on the quality and proper application of these synthetic compounds. But regardless of their composition, the materials used are foreign to human tissue and will elicit a foreign body reaction to a greater or lesser degree. This poster will show the analysis of several types of implanted medical devices from different manufacturers using pyrolysis-GCMS. Traditionally, pyrolysis has been used as a technique to identify polymers, which will be shown. But in addition, one or more "pre-pyrolysis" steps will be programmed first so that we can analyze for residual monomers, solvents, additives and contaminates, if present. Undesired contaminates or the incorrect quantity of an additive can often lead to product failure or worse.Summary: Pyrolysis GC-MS is a standard technique used to analyze industrial polymers. This poster will show the use of multiple temperature ramps to analyze for additives and contaminants, in addition to polymer identification, in several medical devices. Report abuse »
Questions
Ask the author a question about this poster.
Ask a Question »

Creative Commons

Related Posters


High speed untargeted 4D-lipidomics LC-MS/MS workflows with Parallel Accumulation Serial Fragmentation (PASEF)
Ulrike Schweiger-Hufnagel1, Aiko Barsch1, Sven W. Meyer1

TMT Quantification for Shotgun Proteomics on a Trapped-Ion-Mobility quadrupole-Time-Of- Flight mass spectrometer (TIMS-QTOF) powered by Parallel-Accumulation and Serial- Fragmentation (PASEF)
Matt Willetts1, Shourjo Ghose1 Heiner Koch2, Scarlet Koch2, Markus Lubeck2, Gary Kruppa1

Applying Trapped Ion Mobility Separation (TIMS) in combination with Parallel Accumulation Serial Fragmentation (PASEF) for analysis of lipidomics samples
Sebastian Götz1, Sven W Meyer1,Ulrike Schweiger-Hufnagel1,Aiko Barsch1, Ningombam Sanjib Meitei2

Multiplex miRNA Profiling for Biomarker Discovery and Verification Studies Using the FirePlex® Platform
M. Tackett, B. Heinrich, I. Diwan, G. Tejada, C. Rafferty, E. Atabakhsh, and D. Pregibon

PEAKS™ Software for the processing of timsTOF Pro PASEF data: identification and label-free quantitation
Markus Lubeck(1), Heiner Koch(1), Scarlet Beck(1), Paul Savage(2), Oliver Raether(1), Pierre-Olivier Schmit(2) Paul Shan (3) and Gary Kruppa (4)