Analysis of Polymers, Additives and Contaminates in Medical Devices using Pyrolysis-GCMS
EP22872
Poster Title: Analysis of Polymers, Additives and Contaminates in Medical Devices using Pyrolysis-GCMS
Submitted on 06 Apr 2015
Author(s): Gary Deger
Affiliations: CDS Analytical
This poster was presented at Pittcon
Poster Views: 1,727
View poster »


Poster Information
Abstract: Polymers and additives are used in a variety of subcutaneous and intravascular medical devices, such as sutures and drug delivery systems. These devices typically can be classified as being either absorbable or non-absorbable by the human body. Natural materials, such as silk and catgut, are largely being replaced by synthetic materials. So, the reliability of these devices relies on the quality and proper application of these synthetic compounds. But regardless of their composition, the materials used are foreign to human tissue and will elicit a foreign body reaction to a greater or lesser degree. This poster will show the analysis of several types of implanted medical devices from different manufacturers using pyrolysis-GCMS. Traditionally, pyrolysis has been used as a technique to identify polymers, which will be shown. But in addition, one or more "pre-pyrolysis" steps will be programmed first so that we can analyze for residual monomers, solvents, additives and contaminates, if present. Undesired contaminates or the incorrect quantity of an additive can often lead to product failure or worse.Summary: Pyrolysis GC-MS is a standard technique used to analyze industrial polymers. This poster will show the use of multiple temperature ramps to analyze for additives and contaminants, in addition to polymer identification, in several medical devices. Report abuse »
Questions
Ask the author a question about this poster.
Ask a Question »

Creative Commons

Related Posters


Combining Imaging and OMICs: MALDI guided SpatialOMx probes proteomic mass profiles of breast cancer tumor subpopulations
Janina Oetjen 1 , Romano Hebeler 1 , Frédéric Dewez 2 , Corinna Henkel 1 , Benjamin Balluff 2 , Ron Heeren 2

Novel MALDI-TOF MS Workflow for Ultrahigh-Throughput Screening of Different Analytes at Each Position on a Plate
Sergei Dikler

Evaluation of Laser Cleaning of Parchment, Wool and Featherwith High Performance Liquid Chromatography and AttenuatedTotal Reflection -Fourier Transform Infrared Spectroscopy
Stamatis C. Boyatzis, Eleni Ioakimoglou, Eleni Tziamourani, Efrosini Karantoni Ekaterini Malea, Stavroula Rapti, Paraskevi Pouli, Athanassia Papanikolaou, Kristalia Melessanaki, Georgios Panagiaris

FXa Anticoagulant Bioactive Proteins Derived from Scorpion Venom
Meng Li,1 Yuko P. Y. Lam,1 Peng Chen,2 Remy Gavard,1 Cookson K. C. Chiu,1 Christopher A. Wootton,1 Tomos E. Morgan,1 Qiong Wu,2 Mark P. Barrow,1 Hongzheng Fu,2 Peter B. O’Connor1

The Inhibition Pathways of Human Islet Amyloid Polypeptide
Yuko P. Y. Lam1; Cookson K.C. Chiu1; Christopher A. Wootton1; Ji-Inn Song1; Meng Li1; Ian Hands-Portman2; Mark P. Barrow1; and Peter B. O'Connor1