Posters
« Back
Post-Target Analysis of Halogenated Flame Retardants Using Mass Defect Plots
EP22987
Poster Title: Post-Target Analysis of Halogenated Flame Retardants Using Mass Defect Plots
Submitted on 13 May 2015
Author(s): Jonathan D. Byer, Grazina Pacepavicius, Mehran Alaee, Karl Jobst, and Joe Binkley
Affiliations: LECO Corporation, Environment Canada, Ontario Ministry of the Environment
This poster was presented at BFR 2014
Poster Views: 1,176
View poster »


Poster Information
Abstract: Targeted analytical methods are often very robust, sensitive, and selective; yet, a conundrum for many researchers doing complex environmental analysis is "What else is in my sample“? Time-of-flight mass spectrometry (TOFMS) is unsurpassed for non-target analysis because full range mass spectra are acquired simultaneously with minimal mass bias at acquisition rates suitable for narrow gas chromatographic peaks. This provides a number of advantages including the possibility of deconvolving chromatographic interferences using modern software, further enhancing the ability to isolate and identify a greater number of compounds.
 
Analysts are continuously building a tool box for compound discovery which may include multivariate statistical analysis, high resolution mass spectrometry, and soft or selective ionization techniques. Mass defect plots are another tool to add to the analyst’s arsenal. Mass defect is the difference between the nominal and exact masses of a compound or its fragments.1 Halogenated compounds have characteristic mass defects that make them readily distinguishable from most other compound classes. Two fairly recent papers have highlighted the utility of Cl-H mass defect for the identification of halogenated environmental contaminants.2,3 Mass defect (Cl-H) can be calculated according to the following equations, where the IUPAC mass is the observed mass, and the scaling factor for chlorine substituted for hydrogen equals 34/33.960479:
 
Cl-H Scaled Mass = IUPAC Mass × Scaling Factor
 
Cl-H Mass Defect = Cl-H Scaled Mass – Nominal Cl-H Scaled Mass

In this study we used non-target analysis in the form of Cl-H mass defect plots, to identify halogenated contaminants in eels (Anguillia rostrata) from Lake Ontario, Canada. This study was meant to serve as a proof-of-concept for the identification of unknown compounds in complex matrices.
Summary: A number of legacy contaminants and other pesticides were identified in the pooled sample. Cl-H mass defect plots are a useful tool for filtering through complex data for the identification of halogenated contaminants. This technique functions as a screening tool for the identification of unknowns, and in the future, may be used as a form of fingerprinting to compare samples.References: Sleno L. (2012); J Mass Spectrom. 47(2): 226-36

Taguchi VY, Nieckarz RJ, Clement RE, Krolik S, Williams R. (2010); JASMS. 21(11): 1918-21

Jobst KJ, Shen L, Reiner EJ, Taguchi VY, Helm PA, McCrindle R, Backus S. (2013); Anal Bioanal Chem. 405: 3289-97

Byer JD, Lebeuf M, Alaee M, Brown RS, Trottier S, Backus S, Keir M, Couillard CM, Casselman J, Hodson PV. (2013); Chemosphere. 90(5): 1719-28
Report abuse »
Questions
Ask the author a question about this poster.
Ask a Question »

Creative Commons

Related Posters


Identification using Forensic Odontology
Vyom Rathi

FENOLOGÍA, MORFOLOGÍA FLORAL Y PALINOLOGÍA DE Coffea arábica L.
Cristian Camilo Leguízamo Gutiérrez; Monica Patricia Osorio Tangarife, Guillermo Salamanca Grosso

Micropillar-assisted electric field enhancement for high-efficiency inactivation of bacteria
S Pudasaini · A. T. K. Perera · S. S. U. Ahmed · Sum Huan Ng · Chun Yang

Digiceuticals
Helana Lutfi and Shaban Nuredini

Applying Trapped Ion Mobility Separation (TIMS) in combination with Parallel Accumulation Serial Fragmentation (PASEF) for analysis of lipidomics samples
Sebastian Götz1, Sven W Meyer1,Ulrike Schweiger-Hufnagel1,Aiko Barsch1, Ningombam Sanjib Meitei2