Potential Benefits of Comprehensive Two=Dimensional Gas Chromatography — High Resolution Time-of-Flight Mass Spectrometry (GCxGC-HRTOFMS)
EP23004
Poster Title: Potential Benefits of Comprehensive Two=Dimensional Gas Chromatography — High Resolution Time-of-Flight Mass Spectrometry (GCxGC-HRTOFMS)
Submitted on 21 May 2015
Author(s): Mark Merrick, Viatcheslav Artaev
Affiliations: LECO Corporation
This poster was presented at RIVA 2014
Poster Views: 1,011
View poster »


Poster Information
Abstract: GC×GC systems, both commercial and non-commercial, vary in performance. There are two key performance characteristics that determine the performance of a GC×GC system—injection peak width and modulation speed. For typical column configurations (30–60 m first column) an injection peak width with  <10 ms and a modulation period as short as 1 second are required. If either of these are less than optimal, the peak capacity and resolution in the first and second dimensions will be compromised. To obtain the best results from a high performance GC×GC system, the detector must be capable of high data acquisition rates. For a typical GC×GC column configuration, a data acquisition rate of approximately 200 spectra/s is required. Slower detectors are used with sub-optimal GC×GC systems and/or sub-optimal column sets and conditions to match the peak width with the data acquisition rate. GC×GC-TOFMS with nominal mass resolution has demonstrated its high performance in various application areas over the past several years and is considered one of the most powerful techniques for targeted and non-targeted analysis of complex volatile and semi-volatile mixtures.
High resolution mass spectrometry is well-known for its increased selectivity. This poster presents preliminary data for a sewage treatment plant water extract collected on a research prototype GC×GC-HRTOFMS and compares the results of a selected region to those obtained by GC-HRTOFMS.
Summary: Preliminary results of a resarch prototype GC×GC-HRTOFMS demonstrate that more confident peak identifications can be made as compared to GC-HRTOFMS and GC×GC-TOFMS nominal mass. This was possible due to the high mass accuracy, high mass resolution, and high data acquisition rate of the mass spectrometer, and the high performance of the GC×GC system.Report abuse »
Questions
Ask the author a question about this poster.
Ask a Question »

Creative Commons

Related Posters


Recent advances in preventing tobacco related health problems
Dr Ruttika Desai

Identification using Forensic Odontology
Vyom Rathi

Digiceuticals
Helana Lutfi and Shaban Nuredini

Applying Trapped Ion Mobility Separation (TIMS) in combination with Parallel Accumulation Serial Fragmentation (PASEF) for analysis of lipidomics samples
Sebastian Götz1, Sven W Meyer1,Ulrike Schweiger-Hufnagel1,Aiko Barsch1, Ningombam Sanjib Meitei2

Machine Learning: A New Breakthrough in Medical Diagnosis
Punitha Mahendran, Anis Joelaira, Chai Yong Chia, Fazidatul Aziz, Hasyimah Emran, Siew Fun Lee, Wai Kit Wong, Yee Yan Tang, Li Yang Wong