Posters
« Back
Trace Level Analysis of Perchlorate and Bromate in Various Water Matrices using Suppressed Ion Chromatography
EP21788
Poster Title: Trace Level Analysis of Perchlorate and Bromate in Various Water Matrices using Suppressed Ion Chromatography
Submitted on 31 Mar 2014
Author(s): Dr. Jay Gandhi, DR. Stuart Procter
Affiliations: Metrohm USA
Poster Views: 1,234
View poster »


Poster Information
Abstract: Perchlorate salts are used as “rocket fuel” in electroplating and other industries; yet, in 1999 (C&EN article) it was scientifically proven to inhibit the human thyroid gland’s absorption of iodine — which, in turn, may cause thyroid-related diseases. Perchlorate detection/analysis in varying water matrices can be a challenge. How do we overcome the obstacles?
Bromide is ubiquitously found in drinking water. It is introduced into source water either by contact with bromide-containing soils or seawater having a high bromide content. Bromide converts into bromate during water disinfection, for example by ozonation. Bromate can also enter drinking water when sodium hypochlorite is used as disinfectant, as it is a common impurity in sodium hypochlorite production. The International Agency for the Research of Cancer has determined that bromate is a possible carcinogen. Therefore, monitoring of bromate and its precursor bromide in drinking water is required.
While much research has been done to develop methods to analyze for bromate and bromide including several Environmental Protection Agency (EPA) methods, most of this work requires specialized instrumentation such as two-dimensional ion chromatography, expensive sample preparation or post-column reactions techniques.
This work describes a method for determining the concentration of bromate and bromide ions at ppb levels in drinking water using a simple isocratic IC with loop injection. Bottled water and tap water samples were used to validate the method. Spiked water samples were used to verify quantification.
Summary: Bromate and Perchlorate are ubiquitous analytes in various water matrices and analysis in trace level is a challengeReferences: USEPA Method 314.0 enhanced
Metrohm Application Works – AW US6 0071 – Determination of Perchlorate in Various waters (Dual4)
Metrohm Application Works – AW US6 0130 – Determination of Perchlorate in Various waters (ASUPP7)
Metrohm Application Works – AW CH6 0968 – Simultaneous Analysis of Anions and Oxyhalides as per USEPA method 300
Report abuse »